FIXTURE FOR ELECTRIC TESTS OF PUMPS AND LEVEL SENSOR, ASSEMBLY, PRESENCE CHECK, FLOW TESTS, LEAK TESTS AND INK-JET MARKING FOR A WINDSCREEN WASHER FLUID RESERVOIR FOR MACHINE GS-013-TCA
Electric tests of pumps and level sensors, pressure insertion of pumps and sensors, presence checks, flow test, leak test with pressure, ink-jet marking. Fixture inserted in a standard machine with interchangeable fixture GS-013-TCA.
-
FIXTURE FOR TESTING, INSERTING COMPONENTS AND MARKING OF A WINDSCREEN WASHER FLUID RESERVOIR
GENERAL CHARACTERISTICS
- 01 automatic working station with single blocking die
- customized fixture inserted into a standard machine with interchangeable fixture GS-013-TCA
OPERATIONS OF THE AUTOMATIC STATION
- checking of the presence of the fixation holes
- electric test of the pumps
- electric and functional tests of the level sensor to insert
- pressure insertion of the pumps
- pressure insertion of the sensor
- check with optic fibre that the nose of the sensor is still present after the insertion
- leak test with positive pressure of the reservoir
- leak test with positive pressure of the pumps
- ink-jet marking of the good articles
MANUAL OPERATIONS
- unloading of the assembled and tested reservoir
- loading of the reservoir to machine
- loading of the sensor
- loading of the pumps
- starting of the automatic cycle
- preparation of a new reservoir with assembled and lubricated gaskets for the following cycle
-
-